Hinge Systems

94 Page references  TIOMOS Technical information Tiomos mounting plates 76 Accessories 86 Assembly technology 193 Assembly aids 198 TEST CRITERIA FOR HINGES Functional test Static load, vertical Additional load: 20 kg Opening angle: max. -10° Number: 10 Static load horizontal Force: 40 N Number: 10 Endurance test Opening angle: max. -5° Opening and closing movements: 100,000 45° max. -10° 100 mm 40 N 100 mm max. -5° Overload test Vertical Additional load: 30 kg Opening angle: max. -10° Number: 10 Horizontal Force: 80 N Number: 10 Test door Weight approx. 5.2 kg 45° max. -10° 100 mm 100 mm 600 mm 60 mm 60 mm 19 mm 700 mm Salt spray and humidity test Based on DIN ISO 9227 and DIN 6270-2

RkJQdWJsaXNoZXIy ODM0MzI=