137 All dimensions in millimetres. Subject to changes. Hinge systems A Door overlay F Reveal MS Minimum gap SA Number of hinges TA Cup distance TES Door protrusion LEGEND TEST CRITERIA FOR HINGES Functional test Static load, vertical Additional load: 20 kg Opening angle: max. -10° Number: 10 Static load horizontal Force: 40 N Number: 10 Endurance test Opening angle: max. -5° Opening and closing movements: 100,000 45° max. -10° 100 mm 40 N 100 mm max. -5° Overload test Vertical Additional load: 30 kg Opening angle: max. -10° Number: 10 Horizontal Force: 80 N Number: 10 Test door Weight approx. 5.2 kg 45° max. -10° 100 mm 100 mm 600 mm 60 mm 60 mm 19 mm 700 mm Salt spray and humidity test Based on DIN ISO 9227 and DIN 6270-2 NEXIS CLICK-ON
RkJQdWJsaXNoZXIy ODM0MzI=